| cabinet capacity | 90kVA | ||
| module capacity | 15kVA | ||
|
Mains input |
Input Format | 3 phases + N wire + ground | |
| Input Voltage | 380V/400V/415V (line voltage) | ||
| Input frequency | 50/60Hz | ||
| Input power factor | >0.99 | ||
| current harmonic distortion | THDi<3% (100% linear load) | ||
| Voltage range | 207-476Vac | ||
| frequency range | 40-70Hz | ||
|
Bypass |
bypass voltage | 380V/400V/415V (line voltage) | |
|
Voltage range |
220Vac Upper limit: 25% (+10%, +15%, +20% selectable)
Lower limit:-45% (optional -10%, -20%, -30%) |
||
|
frequency range |
Utility mode: ±1%/±2%/±4%/±5%±10% can be set.
Battery mode: (50/60±0.1%) Hz |
||
| Battery | Voltage range | 30-50 12V batteries, even number adjustable, default 40 batteries | |
|
Output |
Output power factor | 1 | |
| Rated output voltage | 380V/400V/415V (line voltage) | ||
| Rated output frequency | 50/60Hz | ||
| voltage accuracy | ±1.0% | ||
| output dynamic response | <5% (0%-100%-0% step load) | ||
| dynamic recovery time | <20ms (0%-100%-0% step load) | ||
| Voltage harmonic distortion | <2% (resistive loads), <5% (non-linear loads) | ||
|
overloaded inverters |
110%, bypass in 1 hour; 125%, bypass in 10 minutes.
150%, bypass after 1 min; >150%, bypass after 200 ms |
||
| frequency accuracy | 50/60Hz±0.1% | ||
| Output Current Peak Ratio | 3:1 | ||
| system efficiency | Normal Mode >96%, Economic Mode >99% | ||
|
system |
protection class | IP20 | |
| communication interface | RS485, parallel card, SNMP card (optional) | ||
| operating temperature | 0-40℃ | ||
| Storage temperature | -25℃ -70℃ | ||
| relative humidity | 0-95% (no condensation) | ||
| Noise (dB) | <60 | ||
Modular Design
Power modules enter intelligent sleep mode and rotate automatically under low loads, further improving operational efficiency.
Power modules support hot-swapping, allowing for on-demand capacity expansion and easy maintenance.
High Reliability
Ultra-wide input voltage range of 207V–476V and ultra-wide input frequency range of 40–70Hz; capable of prolonged operation under overload conditions, providing robust protection for critical downstream loads.
Convenient and Flexible
The chassis supports both standard rack-mount and tower-mount installations, offering flexibility and ease of use
7-inch color touchscreen with graphical display for convenient operation
Flexible configuration of 30–50 battery cells; if a single cell fails, customers do not need to replace the entire battery bank, saving on maintenance costs
Reviews