变频空调

How Inverter and Free-Cooling Technology Reshapes the Energy Consumption Landscape of Data Center Rooms

Product Overview

变频

Cooling Capacity: 5.5kW / 8.5kW / 13.5kW / 17.5kW / 22.5kW / 27kW / 32kW

Voltage: 220V / 380V (50Hz/60Hz available)

Unit Type: Cooling-only, Cooling-only + Electric Heater, Precision Air Conditioning (Constant Temperature & Humidity)

Cooling Mode: Air-Cooled Inverter, Air-Cooled Inverter + Fluoride Pump (Pump-Driven Refrigerant Circulation)

Air Supply Mode: Top Discharge with Air Hood

Applications: Small & Medium-sized Server Rooms, Archives, Rooms without Internal Heat Sources, Outdoor Base Stations, Battery Rooms, Substations, Monitoring Rooms, etc.

Advantages

一、Expansion of the cooling capacity range

Two new models added: 27kW & 32kW
7 cooling capacity options to meet diverse selection needs

The cooling capacity of the unit is increased by 8%~10%.

二、Full Inverter Technology

Variable capacity components equipped as standard across the full range

Variable-Frequency Compressor

image

EC permanent-magnet synchronous motor drive; cooling capacity adjustable from 30% to 100%

On-demand capacity modulation for 30%+ energy savings

30%–100% soft start with low inrush current

Electronic Expansion Valve

image

High control precision, accurate refrigeration

Precise control, stable system

Fast response speed, high precision

Precisely matched to the load, significant energy savings

Indoor EC Fan

image

Soft start from 10% to 100%, low starting current

Driven by EC permanent magnet synchronous motor, remarkable energy savings

Variable air volume supply on demand, saving over 20% energy

Quick-connect power terminals for online hot-swap maintenance

Outdoor Unit

image

Fan blades made of all-metal material, long service life, resistant to deformation

Stepless speed control for energy saving and low noise

Advantages of Full Inverter Design Unit

Enhanced capacity

Wider operating range, adaptable to variable load conditions

Low-load dehumidification capability, suitable for precise temperature control applications without heat sources

Improved unit reliability, stable operation at low load, reduced noise

Dynamic cooling capacity adjustment

74eeeff41f69af45ce82348edf462add

image

Air-Cooled / Fluorine Pump Full Inverter Precision Air Conditioner

Improved energy efficiency

Higher energy efficiency ratio (EER) at partial load

Stable, precise and fast temperature and humidity control with high temperature accuracy

Precise supplementary cooling when combined with fluorine pump natural cooling

Leave a Reply

Your email address will not be published. Required fields are marked *